Is tap water in Gomez, Hobe Sound (33455) safe to drink?
- Port Salerno-Hobe Sound CCD, FL
- Gomez, Hobe Sound
- Hobe Sound
The short answer for Gomez, Hobe Sound (33455)
Hobe Sound tap water has 8 contaminants above EPA guidelines, including PFOS at 3.2× the limit (tested May 2024). See the full compound-by-compound breakdown and filter recommendations.
The health risk for Hobe Sound
- PFBS, PFHxS, PFOA, PFOS, PFPeA above limit.
PFOS (a PFAS 'forever chemical') was detected above EPA limits. These filters are independently certified to reduce common drinking-water contaminants.
Here's what actually removes PFAS from your water
The right filter eliminates PFAS at the tap. But not all filters do - and the type you choose matters for your home.
Common pitchers like Brita do not remove PFAS. You need a filter independently certified to NSF P473 (for pitcher filters) or NSF/ANSI 58 (for reverse osmosis systems). All three options below carry the relevant certification.
| Compound | Measurement | EPA Limit | Comparison |
|---|---|---|---|
| PFOS Tested: May 2024 · North Plant |
0.013 µg/L | 0.004 µg/L | 225% above limit |
| PFOS Tested: July 2024 · South Plant |
0.011 µg/L | 0.004 µg/L | 175% above limit |
| PFOA Tested: May 2024 · North Plant |
0.008 µg/L | 0.004 µg/L | 100% above limit |
| PFBS Tested: July 2024 · South Plant |
0.005 µg/L | 0.003 µg/L | 53% above limit |
| PFPeA Tested: May 2024 · North Plant |
0.004 µg/L | 0.003 µg/L | 47% above limit |
View all tested compounds
North Plant · Tested: Multiple dates
| Compound | Measurement | EPA Limit | Comparison |
|---|---|---|---|
| PFOS | 0.013 µg/L | 0.004 µg/L | 225% above limit |
| PFOA | 0.008 µg/L | 0.004 µg/L | 100% above limit |
| PFPeA | 0.004 µg/L | 0.003 µg/L | 47% above limit |
| PFBS | 0.004 µg/L | 0.003 µg/L | 17% above limit |
| PFHxS | 0.004 µg/L | 0.004 µg/L | 10% above limit |
| PFHxA | 0.004 µg/L | 3 µg/L | 0.1% of limit |
| lithium | <9.000 µg/L | 10 µg/L | Below limit |
| HFPO-DA | <0.005 µg/L | 0.01 µg/L | Below limit |
| PFNA | <0.004 µg/L | 0.01 µg/L | Below limit |
| PFBA | <0.005 µg/L | 6 µg/L | Below limit |
| 11Cl-PF3OUdS | <0.005 µg/L | 0.005 µg/L | Below limit |
| 4:2 FTS | <0.003 µg/L | 0.003 µg/L | Below limit |
| 6:2 FTS | <0.005 µg/L | 0.005 µg/L | Below limit |
| 8:2 FTS | <0.005 µg/L | 0.005 µg/L | Below limit |
| 9Cl-PF3ONS | <0.002 µg/L | 0.002 µg/L | Below limit |
| ADONA | <0.003 µg/L | 0.003 µg/L | Below limit |
| PFDA | <0.003 µg/L | 0.003 µg/L | Below limit |
| PFDoA | <0.003 µg/L | 0.003 µg/L | Below limit |
| PFHpA | <0.003 µg/L | 0.003 µg/L | Below limit |
| PFHpS | <0.003 µg/L | 0.003 µg/L | Below limit |
| PFTrDA | <0.007 µg/L | 0.007 µg/L | Below limit |
| PFUnA | <0.002 µg/L | 0.002 µg/L | Below limit |
South Plant · Tested: Multiple dates
| Compound | Measurement | EPA Limit | Comparison |
|---|---|---|---|
| PFOS | 0.011 µg/L | 0.004 µg/L | 175% above limit |
| PFBS | 0.005 µg/L | 0.003 µg/L | 53% above limit |
| PFOA | 0.004 µg/L | 0.004 µg/L | 3% above limit |
| lithium | <9.000 µg/L | 10 µg/L | Below limit |
| PFHxS | <0.003 µg/L | 0.004 µg/L | Below limit |
| HFPO-DA | <0.005 µg/L | 0.01 µg/L | Below limit |
| PFNA | <0.004 µg/L | 0.01 µg/L | Below limit |
| PFHxA | <0.003 µg/L | 3 µg/L | Below limit |
| PFBA | <0.005 µg/L | 6 µg/L | Below limit |
| 11Cl-PF3OUdS | <0.005 µg/L | 0.005 µg/L | Below limit |
| 4:2 FTS | <0.003 µg/L | 0.003 µg/L | Below limit |
| 6:2 FTS | <0.005 µg/L | 0.005 µg/L | Below limit |
| 8:2 FTS | <0.005 µg/L | 0.005 µg/L | Below limit |
| 9Cl-PF3ONS | <0.002 µg/L | 0.002 µg/L | Below limit |
| ADONA | <0.003 µg/L | 0.003 µg/L | Below limit |
| PFDA | <0.003 µg/L | 0.003 µg/L | Below limit |
| PFDoA | <0.003 µg/L | 0.003 µg/L | Below limit |
| PFHpA | <0.003 µg/L | 0.003 µg/L | Below limit |
| PFHpS | <0.003 µg/L | 0.003 µg/L | Below limit |
| PFPeA | <0.003 µg/L | 0.003 µg/L | Below limit |
| PFTrDA | <0.007 µg/L | 0.007 µg/L | Below limit |
| PFUnA | <0.002 µg/L | 0.002 µg/L | Below limit |
270432080081201 · Tested: Multiple dates
| Compound | Measurement | EPA Limit | Comparison |
|---|---|---|---|
| Arsenic | 0.170 µg/L | 10 µg/L | 2% of limit |
| Lead | 0.200 µg/L | 15 µg/L | 1% of limit |
| Chromium | 0.400 µg/L | 100 µg/L | 0.4% of limit |
| Copper | 2.750 µg/L | 1300 µg/L | 0.2% of limit |
| Nitrate + Nitrite | 2.600 mg/L | 1E+04 mg/L | 0.0% of limit |
| Alkalinity, total | 130.000 mg/L | — | — |
| Aluminum | 5.000 µg/L | — | — |
| Ammonia | 0.002 mg/L | — | — |
| Antimony | 0.170 µg/L | — | — |
| Barium | 4.700 µg/L | — | — |
| Beryllium | 0.010 µg/L | — | — |
| Cadmium | 0.178 µg/L | — | — |
| Calcium | 59.200 mg/L | — | — |
| Chloride | 20.000 mg/L | — | — |
| Escherichia coli | 1.000 MPN/100mL | — | — |
| Fluoride | 0.035 mg/L | — | — |
| Iron | 30.000 µg/L | — | — |
| Magnesium | 1.420 mg/L | — | — |
| Manganese | 1.000 µg/L | — | — |
| Molybdenum | 0.810 µg/L | — | — |
| Nickel | 0.650 µg/L | — | — |
| Nitrogen, mixed forms (NH3)... | 2.900 mg/L | — | — |
| Organic carbon | 0.980 mg/L | — | — |
| Phosphorus | 0.065 mg/L | — | — |
| Potassium | 1.900 mg/L | — | — |
| Purge Volume | 6.640 gal | — | — |
| Selenium | 1.090 µg/L | — | — |
| Silver | 0.010 µg/L | — | — |
| Sodium | 15.900 mg/L | — | — |
| Sulfate | 16.000 mg/L | — | — |
| Thallium | 0.100 µg/L | — | — |
| Total Coliform | 1.000 MPN/100mL | — | — |
| Total dissolved solids | 208.000 mg/L | — | — |
| Total hardness | 154.000 mg/L | — | — |
| Total Kjeldahl nitrogen (Or... | 0.240 mg/L | — | — |
| True color | 2.500 PCU | — | — |
| Zinc | 8.300 µg/L | — | — |
Water utilities serving ZIP 33455
Service area boundaries are approximate and based on state filings or modeled estimates. Contact your utility to confirm exact service at a specific address.
- SOUTH MARTIN REGIONAL UTILITIESAction advised
- SOUNDINGS YACHT ; TENNIS CLUBNo recent federal sampling
Frequently Asked Questions about ZIP 33455 Tap Water
What contaminants are above EPA limits in ZIP 33455?
ZIP 33455 has 8 contaminants above EPA health guidelines in the latest available data, including PFOS at 3.2x the EPA guideline. The full table on this page lists every tested compound and its measured level.
Will boiling ZIP 33455 tap water remove PFOS?
No. Boiling does not remove PFAS, and the compounds can actually become more concentrated as water evaporates. To reduce PFAS at home, use a filter independently certified to NSF/ANSI P473 (activated-carbon pitcher or under-sink) or NSF/ANSI 58 (reverse osmosis).
Do basic pitcher filters remove PFOS?
Most basic pitcher filters are only certified to NSF/ANSI 42 or 53, which do not cover PFAS. Look for a filter independently certified to NSF/ANSI P473 (activated-carbon pitcher or under-sink) or NSF/ANSI 58 (reverse osmosis) on the spec sheet.
Who provides tap water in ZIP 33455?
Public records identify SOUTH MARTIN REGIONAL UTILITIES as a primary water system associated with ZIP 33455. Service boundaries can vary by address, so confirm exact service with the utility.
When was ZIP 33455 tap water last tested?
The most recent test date used in this report is September 2024. EnviroClarity last refreshed this page on 2026-05-05.
Where can I find the official water quality report for ZIP 33455?
Every U.S. public water system is required to publish an annual Consumer Confidence Report (CCR). Contact SOUTH MARTIN REGIONAL UTILITIES or visit their website for the latest official report covering ZIP 33455. The EPA also maintains a national CCR locator.
Check another ZIP code
Nearby ZIP reports
- 33475 - Hobe Sound tap water report
- 34992 - Port Salerno tap water report
- 34997 - Indiantown CCD, Port Salerno tap water report
- 33469 - Tequesta tap water report
- 34996 - Sewall's Point tap water report
- 34994 - Stuart tap water report
- 33458 - Port Salerno-Hobe Sound CCD, Jupiter tap water report
- 34990 - Palm City tap water report
Data reflects publicly reported utility records from EPA datasets and local utility disclosures. This information is educational and not medical advice.