Is tap water in Fort McCoy-Anthony CCD (34475) safe to drink?
- Ocala CCD, FL
- Fort McCoy-Anthony CCD, FL
- Ocala
The short answer for Fort McCoy-Anthony CCD (34475)
Ocala tap water has 11 contaminants above EPA guidelines, including PFHxS at 10.2× the limit (tested July 2024). See the full compound-by-compound breakdown and filter recommendations.
The health risk for Ocala
- PFBS, PFHpA, PFHxS, PFOA, PFOS, PFPeA above limit.
PFHxS (a PFAS 'forever chemical') was detected above EPA limits. These filters are independently certified to reduce common drinking-water contaminants.
Here's what actually removes PFAS from your water
The right filter eliminates PFAS at the tap. But not all filters do - and the type you choose matters for your home.
Common pitchers like Brita do not remove PFAS. You need a filter independently certified to NSF P473 (for pitcher filters) or NSF/ANSI 58 (for reverse osmosis systems). All three options below carry the relevant certification.
| Compound | Measurement | EPA Limit | Comparison |
|---|---|---|---|
| PFHxS Tested: July 2024 · Ocala Water Plant |
0.041 µg/L | 0.004 µg/L | 925% above limit |
| PFOS Tested: July 2024 · Ocala Water Plant |
0.039 µg/L | 0.004 µg/L | 875% above limit |
| PFPeA Tested: July 2024 · Ocala Water Plant |
0.014 µg/L | 0.003 µg/L | 367% above limit |
| PFBS Tested: July 2024 · Ocala Water Plant |
0.009 µg/L | 0.003 µg/L | 183% above limit |
| PFHpA Tested: July 2024 · Ocala Water Plant |
0.006 µg/L | 0.003 µg/L | 110% above limit |
View all tested compounds
Ocala Water Plant · Tested: July 2024
| Compound | Measurement | EPA Limit | Comparison |
|---|---|---|---|
| PFHxS | 0.041 µg/L | 0.004 µg/L | 925% above limit |
| PFOS | 0.039 µg/L | 0.004 µg/L | 875% above limit |
| PFPeA | 0.014 µg/L | 0.003 µg/L | 367% above limit |
| PFBS | 0.009 µg/L | 0.003 µg/L | 183% above limit |
| PFHpA | 0.006 µg/L | 0.003 µg/L | 110% above limit |
| PFOA | 0.006 µg/L | 0.004 µg/L | 62% above limit |
| PFHxA | 0.012 µg/L | 3 µg/L | 0.4% of limit |
| PFBA | 0.006 µg/L | 6 µg/L | 0.1% of limit |
| lithium | <9.000 µg/L | 10 µg/L | Below limit |
| HFPO-DA | <0.005 µg/L | 0.01 µg/L | Below limit |
| PFNA | <0.004 µg/L | 0.01 µg/L | Below limit |
| 11Cl-PF3OUdS | <0.005 µg/L | 0.005 µg/L | Below limit |
| 4:2 FTS | <0.003 µg/L | 0.003 µg/L | Below limit |
| 6:2 FTS | <0.005 µg/L | 0.005 µg/L | Below limit |
| 8:2 FTS | <0.005 µg/L | 0.005 µg/L | Below limit |
| 9Cl-PF3ONS | <0.002 µg/L | 0.002 µg/L | Below limit |
| ADONA | <0.003 µg/L | 0.003 µg/L | Below limit |
| PFDA | <0.003 µg/L | 0.003 µg/L | Below limit |
| PFDoA | <0.003 µg/L | 0.003 µg/L | Below limit |
| PFHpS | <0.003 µg/L | 0.003 µg/L | Below limit |
| PFTrDA | <0.007 µg/L | 0.007 µg/L | Below limit |
| PFUnA | <0.002 µg/L | 0.002 µg/L | Below limit |
OCALA HEIGHTS Treatment Plant · Tested: August 2025
| Compound | Measurement | EPA Limit | Comparison |
|---|---|---|---|
| PFBS | 0.006 µg/L | 0.003 µg/L | 93% above limit |
| PFPeA | 0.005 µg/L | 0.003 µg/L | 83% above limit |
| PFOS | 0.006 µg/L | 0.004 µg/L | 60% above limit |
| PFOA | 0.006 µg/L | 0.004 µg/L | 55% above limit |
| PFHxS | 0.004 µg/L | 0.004 µg/L | 7% above limit |
| PFHxA | 0.004 µg/L | 3 µg/L | 0.1% of limit |
| lithium | <9.000 µg/L | 10 µg/L | Below limit |
| HFPO-DA | <0.005 µg/L | 0.01 µg/L | Below limit |
| PFNA | <0.004 µg/L | 0.01 µg/L | Below limit |
| PFBA | <0.005 µg/L | 6 µg/L | Below limit |
| 11Cl-PF3OUdS | <0.005 µg/L | 0.005 µg/L | Below limit |
| 4:2 FTS | <0.003 µg/L | 0.003 µg/L | Below limit |
| 6:2 FTS | <0.005 µg/L | 0.005 µg/L | Below limit |
| 8:2 FTS | <0.005 µg/L | 0.005 µg/L | Below limit |
| 9Cl-PF3ONS | <0.002 µg/L | 0.002 µg/L | Below limit |
| ADONA | <0.003 µg/L | 0.003 µg/L | Below limit |
| PFDA | <0.003 µg/L | 0.003 µg/L | Below limit |
| PFDoA | <0.003 µg/L | 0.003 µg/L | Below limit |
| PFHpA | <0.003 µg/L | 0.003 µg/L | Below limit |
| PFHpS | <0.003 µg/L | 0.003 µg/L | Below limit |
| PFTrDA | <0.007 µg/L | 0.007 µg/L | Below limit |
| PFUnA | <0.002 µg/L | 0.002 µg/L | Below limit |
M-0419 · Tested: Multiple dates
| Compound | Measurement | EPA Limit | Comparison |
|---|---|---|---|
| Arsenic | 0.729 µg/L | 10 µg/L | 7% of limit |
| Chromium | 2.145 µg/L | 100 µg/L | 2% of limit |
| Lead | 0.050 µg/L | 15 µg/L | 0.3% of limit |
| Copper | 2.599 µg/L | 1300 µg/L | 0.2% of limit |
| Nitrate + Nitrite | 1.274 mg/L | 1E+04 mg/L | 0.0% of limit |
| Alkalinity, total | 300.804 mg/L | — | — |
| Aluminum | 5.000 µg/L | — | — |
| Ammonia-nitrogen | 0.005 mg/L | — | — |
| Antimony | 0.500 µg/L | — | — |
| Barium | 2.515 µg/L | — | — |
| Beryllium | 0.050 µg/L | — | — |
| Cadmium | 0.050 µg/L | — | — |
| Calcium | 108.346 mg/L | — | — |
| Chloride | 3.260 mg/L | — | — |
| Iron | 8.736 µg/L | — | — |
| Magnesium | 1.682 mg/L | — | — |
| Manganese | 0.500 µg/L | — | — |
| Molybdenum | 1.000 µg/L | — | — |
| Nickel | 0.734 µg/L | — | — |
| Organic carbon | 2.600 mg/L | — | — |
| Orthophosphate | 0.064 mg/L | — | — |
| Phosphorus | 0.096 mg/L | — | — |
| Potassium | 0.500 mg/L | — | — |
| Selenium | 5.000 µg/L | — | — |
| Silver | 0.050 µg/L | — | — |
| Sodium | 4.293 mg/L | — | — |
| Strontium | 78.086 µg/L | — | — |
| Sulfate | 3.110 mg/L | — | — |
| Thallium | 0.050 µg/L | — | — |
| Tin | 0.500 µg/L | — | — |
| Total dissolved solids | 280.000 mg/L | — | — |
| Total hardness | 333.998 mg/L | — | — |
| Total Kjeldahl nitrogen (Or... | 0.057 mg/L | — | — |
| Vanadium | 10.777 µg/L | — | — |
| Water level in well, depth ... | 43.450 ft | — | — |
| Zinc | 13.258 µg/L | — | — |
Water utilities serving ZIP 34475
Service area boundaries are approximate and based on state filings or modeled estimates. Contact your utility to confirm exact service at a specific address.
- OCALA HEIGHTS S/DAction advised
- OCALA, CITY OF (2 WTPS)Action advised
- M-0419 (WQP)No recent federal sampling
Frequently Asked Questions about ZIP 34475 Tap Water
What contaminants are above EPA limits in ZIP 34475?
ZIP 34475 has 11 contaminants above EPA health guidelines in the latest available data, including PFHxS at 10.2x the EPA guideline. The full table on this page lists every tested compound and its measured level.
Will boiling ZIP 34475 tap water remove PFHxS?
No. Boiling does not remove PFAS, and the compounds can actually become more concentrated as water evaporates. To reduce PFAS at home, use a filter independently certified to NSF/ANSI P473 (activated-carbon pitcher or under-sink) or NSF/ANSI 58 (reverse osmosis).
Do basic pitcher filters remove PFHxS?
Most basic pitcher filters are only certified to NSF/ANSI 42 or 53, which do not cover PFAS. Look for a filter independently certified to NSF/ANSI P473 (activated-carbon pitcher or under-sink) or NSF/ANSI 58 (reverse osmosis) on the spec sheet.
Who provides tap water in ZIP 34475?
Public records identify OCALA HEIGHTS S/D as a primary water system associated with ZIP 34475. Service boundaries can vary by address, so confirm exact service with the utility.
When was ZIP 34475 tap water last tested?
The most recent test date used in this report is August 2025. EnviroClarity last refreshed this page on 2026-05-05.
Where can I find the official water quality report for ZIP 34475?
Every U.S. public water system is required to publish an annual Consumer Confidence Report (CCR). Contact OCALA HEIGHTS S/D or visit their website for the latest official report covering ZIP 34475. The EPA also maintains a national CCR locator.
Check another ZIP code
Nearby ZIP reports
- 34479 - Silver Springs, Ocala tap water report
- 34482 - Fellowship CCD, Ocala tap water report
- 34421 - Belleview tap water report
- 34489 - Silver Springs tap water report
- 34477 - Ocala tap water report
- 34478 - Ocala tap water report
- 32192 - Sparr tap water report
- 34470 - Silver Springs, Ocala tap water report
Data reflects publicly reported utility records from EPA datasets and local utility disclosures. This information is educational and not medical advice.