Is tap water in East Marion CCD (34488) safe to drink?
- East Marion CCD, FL
- Ocala CCD, FL
- Silver Springs
The short answer for East Marion CCD (34488)
Silver Springs tap water has 6 contaminants above EPA guidelines, including PFHxS at 10.2× the limit (tested July 2024). See the full compound-by-compound breakdown and filter recommendations.
The health risk for Silver Springs
- PFBS, PFHpA, PFHxS, PFOA, PFOS, PFPeA above limit.
PFHxS (a PFAS 'forever chemical') was detected above EPA limits. These filters are independently certified to reduce common drinking-water contaminants.
Here's what actually removes PFAS from your water
The right filter eliminates PFAS at the tap. But not all filters do - and the type you choose matters for your home.
Common pitchers like Brita do not remove PFAS. You need a filter independently certified to NSF P473 (for pitcher filters) or NSF/ANSI 58 (for reverse osmosis systems). All three options below carry the relevant certification.
| Compound | Measurement | EPA Limit | Comparison |
|---|---|---|---|
| PFHxS Tested: July 2024 · Ocala Water Plant |
0.041 µg/L | 0.004 µg/L | 925% above limit |
| PFOS Tested: July 2024 · Ocala Water Plant |
0.039 µg/L | 0.004 µg/L | 875% above limit |
| PFPeA Tested: July 2024 · Ocala Water Plant |
0.014 µg/L | 0.003 µg/L | 367% above limit |
| PFBS Tested: July 2024 · Ocala Water Plant |
0.009 µg/L | 0.003 µg/L | 183% above limit |
| PFHpA Tested: July 2024 · Ocala Water Plant |
0.006 µg/L | 0.003 µg/L | 110% above limit |
View all tested compounds
Ocala Water Plant · Tested: July 2024
| Compound | Measurement | EPA Limit | Comparison |
|---|---|---|---|
| PFHxS | 0.041 µg/L | 0.004 µg/L | 925% above limit |
| PFOS | 0.039 µg/L | 0.004 µg/L | 875% above limit |
| PFPeA | 0.014 µg/L | 0.003 µg/L | 367% above limit |
| PFBS | 0.009 µg/L | 0.003 µg/L | 183% above limit |
| PFHpA | 0.006 µg/L | 0.003 µg/L | 110% above limit |
| PFOA | 0.006 µg/L | 0.004 µg/L | 62% above limit |
| PFHxA | 0.012 µg/L | 3 µg/L | 0.4% of limit |
| PFBA | 0.006 µg/L | 6 µg/L | 0.1% of limit |
| lithium | <9.000 µg/L | 10 µg/L | Below limit |
| HFPO-DA | <0.005 µg/L | 0.01 µg/L | Below limit |
| PFNA | <0.004 µg/L | 0.01 µg/L | Below limit |
| 11Cl-PF3OUdS | <0.005 µg/L | 0.005 µg/L | Below limit |
| 4:2 FTS | <0.003 µg/L | 0.003 µg/L | Below limit |
| 6:2 FTS | <0.005 µg/L | 0.005 µg/L | Below limit |
| 8:2 FTS | <0.005 µg/L | 0.005 µg/L | Below limit |
| 9Cl-PF3ONS | <0.002 µg/L | 0.002 µg/L | Below limit |
| ADONA | <0.003 µg/L | 0.003 µg/L | Below limit |
| PFDA | <0.003 µg/L | 0.003 µg/L | Below limit |
| PFDoA | <0.003 µg/L | 0.003 µg/L | Below limit |
| PFHpS | <0.003 µg/L | 0.003 µg/L | Below limit |
| PFTrDA | <0.007 µg/L | 0.007 µg/L | Below limit |
| PFUnA | <0.002 µg/L | 0.002 µg/L | Below limit |
M-0044 · Tested: Multiple dates
| Compound | Measurement | EPA Limit | Comparison |
|---|---|---|---|
| Arsenic | 0.500 µg/L | 10 µg/L | 5% of limit |
| Chromium | 0.500 µg/L | 100 µg/L | 0.5% of limit |
| Lead | 0.050 µg/L | 15 µg/L | 0.3% of limit |
| Copper | 0.502 µg/L | 1300 µg/L | 0.0% of limit |
| Nitrate + Nitrite | 0.012 mg/L | 1E+04 mg/L | 0.0% of limit |
| Alkalinity, total | 198.145 mg/L | — | — |
| Aluminum | 5.130 µg/L | — | — |
| Ammonia | 0.320 mg/L | — | — |
| Ammonia-nitrogen | 0.256 mg/L | — | — |
| Antimony | 0.500 µg/L | — | — |
| Barium | 9.311 µg/L | — | — |
| Beryllium | 0.050 µg/L | — | — |
| Cadmium | 0.050 µg/L | — | — |
| Calcium | 55.850 mg/L | — | — |
| Chloride | 6.850 mg/L | — | — |
| Escherichia coli | 1.000 MPN/100mL | — | — |
| Fluoride | 0.350 mg/L | — | — |
| Iron | 724.080 µg/L | — | — |
| Magnesium | 13.265 mg/L | — | — |
| Manganese | 26.206 µg/L | — | — |
| Molybdenum | 1.515 µg/L | — | — |
| Nickel | 0.500 µg/L | — | — |
| Nitrogen, mixed forms (NH3)... | 0.370 mg/L | — | — |
| Organic carbon | 3.444 mg/L | — | — |
| Orthophosphate | 0.213 mg/L | — | — |
| Phosphorus | 0.256 mg/L | — | — |
| Potassium | 0.977 mg/L | — | — |
| Purge Volume | 188.000 gal | — | — |
| Selenium | 5.000 µg/L | — | — |
| Silver | 0.053 µg/L | — | — |
| Sodium | 5.024 mg/L | — | — |
| Strontium | 78.219 µg/L | — | — |
| Sulfate | 3.000 mg/L | — | — |
| Thallium | 0.050 µg/L | — | — |
| Tin | 0.500 µg/L | — | — |
| Total Coliform | 1.000 MPN/100mL | — | — |
| Total dissolved solids | 230.000 mg/L | — | — |
| Total hardness | 194.082 mg/L | — | — |
| Total Kjeldahl nitrogen (Or... | 0.366 mg/L | — | — |
| True color | 12.000 PCU | — | — |
| Vanadium | 0.500 µg/L | — | — |
| Water level in well, depth ... | 9.980 ft | — | — |
| Zinc | 5.639 µg/L | — | — |
Water utilities serving ZIP 34488
Service area boundaries are approximate and based on state filings or modeled estimates. Contact your utility to confirm exact service at a specific address.
- OCALA, CITY OF (2 WTPS)Action advised
- M-0044 (WQP)No recent federal sampling
Frequently Asked Questions about ZIP 34488 Tap Water
What contaminants are above EPA limits in ZIP 34488?
ZIP 34488 has 6 contaminants above EPA health guidelines in the latest available data, including PFHxS at 10.2x the EPA guideline. The full table on this page lists every tested compound and its measured level.
Will boiling ZIP 34488 tap water remove PFHxS?
No. Boiling does not remove PFAS, and the compounds can actually become more concentrated as water evaporates. To reduce PFAS at home, use a filter independently certified to NSF/ANSI P473 (activated-carbon pitcher or under-sink) or NSF/ANSI 58 (reverse osmosis).
Do basic pitcher filters remove PFHxS?
Most basic pitcher filters are only certified to NSF/ANSI 42 or 53, which do not cover PFAS. Look for a filter independently certified to NSF/ANSI P473 (activated-carbon pitcher or under-sink) or NSF/ANSI 58 (reverse osmosis) on the spec sheet.
Who provides tap water in ZIP 34488?
Public records identify OCALA, CITY OF (2 WTPS) as a primary water system associated with ZIP 34488. Service boundaries can vary by address, so confirm exact service with the utility.
When was ZIP 34488 tap water last tested?
The most recent test date used in this report is July 2024. EnviroClarity last refreshed this page on 2026-05-05.
Where can I find the official water quality report for ZIP 34488?
Every U.S. public water system is required to publish an annual Consumer Confidence Report (CCR). Contact OCALA, CITY OF (2 WTPS) or visit their website for the latest official report covering ZIP 34488. The EPA also maintains a national CCR locator.
Check another ZIP code
Nearby ZIP reports
- 34421 - Belleview tap water report
- 34470 - Silver Springs, Ocala tap water report
- 34489 - Silver Springs tap water report
- 34479 - Silver Springs, Ocala tap water report
- 34472 - Silver Springs Shores tap water report
- 32192 - Sparr tap water report
- 32134 - Lake Kerr tap water report
- 34478 - Ocala tap water report
Data reflects publicly reported utility records from EPA datasets and local utility disclosures. This information is educational and not medical advice.