Is tap water in Ormond Beach CCD (32117) safe to drink?
- Ormond Beach CCD, FL
- Daytona Beach CCD, FL
- Daytona Beach
The short answer for Ormond Beach CCD (32117)
Daytona Beach tap water has 2 contaminants above EPA guidelines, including PFHxS at 1.7× the limit (tested August 2024). See the full compound-by-compound breakdown and filter recommendations.
The health risk for Daytona Beach
- PFHxS, PFPeA above limit.
PFHxS (a PFAS 'forever chemical') was detected above EPA limits. These filters are independently certified to reduce common drinking-water contaminants.
Here's what actually removes PFAS from your water
The right filter eliminates PFAS at the tap. But not all filters do - and the type you choose matters for your home.
Common pitchers like Brita do not remove PFAS. You need a filter independently certified to NSF P473 (for pitcher filters) or NSF/ANSI 58 (for reverse osmosis systems). All three options below carry the relevant certification.
| Compound | Measurement | EPA Limit | Comparison |
|---|---|---|---|
| PFHxS Tested: August 2024 · Brennan Water TP |
0.007 µg/L | 0.004 µg/L | 72% above limit |
| PFPeA Tested: August 2024 · Brennan Water TP |
0.003 µg/L | 0.003 µg/L | 7% above limit |
View all tested compounds
Brennan Water TP · Tested: Multiple dates
| Compound | Measurement | EPA Limit | Comparison |
|---|---|---|---|
| PFHxS | 0.007 µg/L | 0.004 µg/L | 72% above limit |
| PFPeA | 0.003 µg/L | 0.003 µg/L | 7% above limit |
| lithium | <9.000 µg/L | 10 µg/L | Below limit |
| HFPO-DA | <0.005 µg/L | 0.01 µg/L | Below limit |
| PFNA | <0.004 µg/L | 0.01 µg/L | Below limit |
| PFHxA | <0.003 µg/L | 3 µg/L | Below limit |
| PFBA | <0.005 µg/L | 6 µg/L | Below limit |
| 11Cl-PF3OUdS | <0.005 µg/L | 0.005 µg/L | Below limit |
| 4:2 FTS | <0.003 µg/L | 0.003 µg/L | Below limit |
| 6:2 FTS | <0.005 µg/L | 0.005 µg/L | Below limit |
| 8:2 FTS | <0.005 µg/L | 0.005 µg/L | Below limit |
| 9Cl-PF3ONS | <0.002 µg/L | 0.002 µg/L | Below limit |
| ADONA | <0.003 µg/L | 0.003 µg/L | Below limit |
| PFBS | <0.003 µg/L | 0.003 µg/L | Below limit |
| PFDA | <0.003 µg/L | 0.003 µg/L | Below limit |
| PFDoA | <0.003 µg/L | 0.003 µg/L | Below limit |
| PFHpA | <0.003 µg/L | 0.003 µg/L | Below limit |
| PFHpS | <0.003 µg/L | 0.003 µg/L | Below limit |
| PFOA | <0.004 µg/L | 0.004 µg/L | Below limit |
| PFOS | <0.004 µg/L | 0.004 µg/L | Below limit |
| PFTrDA | <0.007 µg/L | 0.007 µg/L | Below limit |
| PFUnA | <0.002 µg/L | 0.002 µg/L | Below limit |
V-0127 · Tested: Multiple dates
| Compound | Measurement | EPA Limit | Comparison |
|---|---|---|---|
| Lead | 2.606 µg/L | 15 µg/L | 17% of limit |
| Arsenic | 0.500 µg/L | 10 µg/L | 5% of limit |
| Chromium | 0.947 µg/L | 100 µg/L | 0.9% of limit |
| Copper | 0.500 µg/L | 1300 µg/L | 0.0% of limit |
| Nitrate + Nitrite | 0.010 mg/L | 1E+04 mg/L | 0.0% of limit |
| Alkalinity, total | 290.003 mg/L | — | — |
| Aluminum | 59.793 µg/L | — | — |
| Ammonia-nitrogen | 0.364 mg/L | — | — |
| Antimony | 0.500 µg/L | — | — |
| Barium | 21.160 µg/L | — | — |
| Beryllium | 0.050 µg/L | — | — |
| Cadmium | 0.050 µg/L | — | — |
| Calcium | 110.322 mg/L | — | — |
| Chloride | 12.680 mg/L | — | — |
| Iron | 3992.704 µg/L | — | — |
| Magnesium | 7.232 mg/L | — | — |
| Manganese | 37.511 µg/L | — | — |
| Molybdenum | 1.000 µg/L | — | — |
| Nickel | 0.500 µg/L | — | — |
| Organic carbon | 11.310 mg/L | — | — |
| Orthophosphate | 0.168 mg/L | — | — |
| Phosphorus | 0.204 mg/L | — | — |
| Potassium | 1.032 mg/L | — | — |
| Selenium | 5.000 µg/L | — | — |
| Silver | 0.050 µg/L | — | — |
| Sodium | 13.152 mg/L | — | — |
| Strontium | 413.603 µg/L | — | — |
| Sulfate | 3.000 mg/L | — | — |
| Thallium | 0.050 µg/L | — | — |
| Tin | 0.500 µg/L | — | — |
| Total dissolved solids | 365.000 mg/L | — | — |
| Total hardness | 305.256 mg/L | — | — |
| Total Kjeldahl nitrogen (Or... | 0.610 mg/L | — | — |
| Vanadium | 3.590 µg/L | — | — |
| Water level in well, depth ... | 7.850 ft | — | — |
| Zinc | 5.000 µg/L | — | — |
Water TP · Tested: September 2024
| Compound | Measurement | EPA Limit | Comparison |
|---|---|---|---|
| lithium | <9.000 µg/L | 10 µg/L | Below limit |
| PFTrDA | <0.007 µg/L | 0.007 µg/L | Below limit |
Water utilities serving ZIP 32117
Service area boundaries are approximate and based on state filings or modeled estimates. Contact your utility to confirm exact service at a specific address.
- DAYTONA BEACH, CITY OFAction advised
- CITY OF HOLLY HILLLooks OK
- V-0127 (WQP)No recent federal sampling
Frequently Asked Questions about ZIP 32117 Tap Water
What contaminants are above EPA limits in ZIP 32117?
ZIP 32117 has 2 contaminants above EPA health guidelines in the latest available data, including PFHxS at 1.7x the EPA guideline. The full table on this page lists every tested compound and its measured level.
Will boiling ZIP 32117 tap water remove PFHxS?
No. Boiling does not remove PFAS, and the compounds can actually become more concentrated as water evaporates. To reduce PFAS at home, use a filter independently certified to NSF/ANSI P473 (activated-carbon pitcher or under-sink) or NSF/ANSI 58 (reverse osmosis).
Do basic pitcher filters remove PFHxS?
Most basic pitcher filters are only certified to NSF/ANSI 42 or 53, which do not cover PFAS. Look for a filter independently certified to NSF/ANSI P473 (activated-carbon pitcher or under-sink) or NSF/ANSI 58 (reverse osmosis) on the spec sheet.
Who provides tap water in ZIP 32117?
Public records identify DAYTONA BEACH, CITY OF as a primary water system associated with ZIP 32117. Service boundaries can vary by address, so confirm exact service with the utility.
When was ZIP 32117 tap water last tested?
The most recent test date used in this report is September 2024. EnviroClarity last refreshed this page on 2026-05-05.
Where can I find the official water quality report for ZIP 32117?
Every U.S. public water system is required to publish an annual Consumer Confidence Report (CCR). Contact DAYTONA BEACH, CITY OF or visit their website for the latest official report covering ZIP 32117. The EPA also maintains a national CCR locator.
Check another ZIP code
Nearby ZIP reports
- 32114 - Daytona Beach CCD, Daytona Beach tap water report
- 32118 - North Peninsula CCD, Daytona Beach tap water report
- 32174 - Central Volusia CCD, Ormond Beach tap water report
- 32119 - Port Orange CCD, Daytona Beach tap water report
- 32176 - North Peninsula CCD, Ormond Beach tap water report
- 32129 - Port Orange CCD, Port Orange tap water report
- 32124 - Central Volusia CCD, Daytona Beach tap water report
- 32127 - Ponce Inlet, Port Orange tap water report
Data reflects publicly reported utility records from EPA datasets and local utility disclosures. This information is educational and not medical advice.